Measurement Performance Enhancing Features
Scroll
LS-1881A | LS-R902 | LS-R902EV | LS-R912 | LS-R700 | LS-1866 | |
---|---|---|---|---|---|---|
100 channels Up to 100 channels can be set to handle a wide variety of works. |
||||||
CISVAS Filter This function uses Cosmo’s unique algorithm to filter out measurement noise that can cause erroneous judgments due to sudden deformation of the works. |
||||||
Intelligent Pneumatic Circuit Leak detection circuit with internal pressure detection method, available in Intelligent 1 Pneumatic Circuit and Intelligent 2 Pneumatic Circuit. The differential pressure sensor and air operated valves are integrated with the manifold in a highly durable structure that minimizes breakdowns. In each test, the differential pressure sensor and the valves are self-checked to ensure that the judgment result is reliable. |
||||||
High-performance differential pressure sensor The improved differential pressure sensor, which is the heart of the Air Leak Tester, and the high-performance AD converter have realized measurement stability in units of 0.1 Pa. These effects are expected to improve measurement accuracy and shorten test time. |
||||||
Mastering / Master Preset Error components due to adiabatic compression, deformation, etc. during measurement are extracted and compensated using the value, enabling testing with a considerable error component, reducing measurement time and at the same time facilitating control on the master side. In addition, the system follows gradual environmental changes, such as room temperature, to achieve more stable measurements. |
||||||
Temperature Compensation When there are differences in the temperatures of the works, the detection capability is improved by compensating for the differences for measurement. |
||||||
Ambient Temperature Compensation This function monitors the ambient temperature in real time during leak measurements and compensates for measurement noise generated by changes in ambient temperature, which can cause erroneous readings. |
||||||
Leak calibratrion To display differential pressure due to leak in flow units such as mL/min, a flow coefficient (Equivalent Internal Volume) is required. There are two methods to measure this coefficient: the volumetric change method and the Leak Master method. In addition, the fully-automated ALC (volumetric change method) and the automatic Leak Master provide the K-check function that not only measures the flow coefficient but also automatically checks for changes in leak sensitivity. |
||||||
Multi-pneumatic circuit unit control Up to 8 pneumatic cirtuit units connected to and controlled by a Controller reduces costs. Separately installed pneumatic circuit units realizes space saving. |
- Standard feature
- Optional feature
Safety and Reliability Enhancing Features
Scroll
LS-1881A | LS-R902 | LS-R902EV | LS-R912 | LS-R700 | LS-1866 | |
---|---|---|---|---|---|---|
Automatic setup Allows users to change their password. |
||||||
Blockage Check Memorizes the normal measurement status of secondary-side equipment and diagnoses whether external exhaust valves, switching valves, etc. are blocked. |
||||||
Optimum Value Detection Detects the change in differential pressure in Detection, which is the most stable and has the least noise, and converts it into a leak value. |
||||||
Password setting Allows users to change their password. |
||||||
Manual valve monitoring Automatically checks the opening and closing of the manual valves used for leak check of the tester itself. Detects if the valve(s) are left closed after a leak check, preventing leak testing with the valves closed. |
||||||
Calibration port A port provided on the front panel for daily inspection and leak calibration. Differential pressure and test pressure can also be inspected and calibrated. |
||||||
NR (Noise Reduction) When the leak limit is lowered to pursue accuracy or to shorten measurement time, the ratio of noise to the measured value will increase. In the Noise Reduction (NR) mode, indeterminate judgment areas are set for the initial Detection, and if the work falls within one of these areas, the noise component is removed by repeating Detection so that false rejection of good works can be reduced. |
||||||
External Exhaust Valve To prevent malfunctions due to water or oil inside the works entering the tester, an externally installed exhaust valve (optional) is controlled by the tester. |
||||||
Exhaust Interference Prevention For a system with multiple leak testers, the exhaust process can cause large fluctuations in the source pressure. It can have a negative impact on the tester(s) that are still measuring. This function is provided to prevent this problem. |
- Standard feature
- Optional feature
Functions related to the interface
Scroll
LS-1881A | LS-R902 | LS-R902EV | LS-R912 | LS-R700 | LS-1866 | |
---|---|---|---|---|---|---|
Color touch panel LCD Easy-to-understand large color touch panel LCD allows intuitive operation. |
||||||
Fieldbus By connecting the tester and PLC via a fieldbus, the communication cables can be significantly reduced, and settings can be easily made with the EDS file provided by us. |
||||||
Quality management The latest 1000 work data (5000 for LS-R902) can be stored and displayed in a graph, which is useful for monitoring changes in work characteristics and changes in the measurement environment. In addition, the Mastering characteristic graph makes it easier to set test conditions. |
||||||
USB memory data storage A USB memory can be used to store large amounts of data for long periods of time, and data can be easily transferred to a PC. |
||||||
FTP function Allows you to send and receive files using FTP client software. |
||||||
Multilingual Allows you to switch the display between multiple languages, including Japanese, English, and Chinese. |
||||||
I/O monitor Check the connection of the signals with external PLCs, such as start/stop signals and pass/fail signals, on the screen. This is very useful when equipment is connected. |
- Standard feature
- Optional feature
Pneumatic Circuit
Scroll
LS-1881A | LS-R902 | LS-R902EV | LS-R912 | LS-R700 | LS-1866 | |
---|---|---|---|---|---|---|
Test pressure 2-port switching One of two different test pressures can be assigned to each channel. Switching between pressure and vacuum and fast charging are also possible. |
||||||
Test pressure 2-circuit switching Allows the tester to switch between two test pressure circuits using the combination of a precision regulator and an E/P regulator. |
||||||
Test pressure control by electro-pneumatic regulator Test pressure is remotely controlled by an E/P regulator. Different settings for each channel and high-speed charging are possible. |
||||||
Bypass circuit To reduce pressurization time for large-volume works, the tester directly controls the valve of an externally installed bypass circuit unit (optional). |
||||||
High-pressure compatible Supports leak testing at test pressures in excess of 1 MPa. |