Overview of differential pressure sensor

Principle

Due to magnetic flat diaphragm being used in pressure receiving part, micro displacement detected as impedance change.
And safety wall preserve the diaphragm against excess pressure.

Silent feature

  • Linearity range: 0 〜 ±1000 Pa or 2,000 Pa (Depends on model)
  • High Sensitivity optical resolution: 1Pa or 0.1 Pa (Depends on model)
  • High Proof pressure Standard: 5 MPa (Max 16Mpa)
  • Volume deviation ratio: 0.01 ml/kPa or 0.005 mL/kPa (Depends on model)
Cross-sectional view of the sensor