Menu

Language

ls-r740-ssの斜め
ls-r740-ssのセット

LS-R740 (SS) DP Leak Testers

  • Separate type
  • For micro volume works
Air Leak Tester for Micro Volume Works
Air Leak Tester with a small internal volume. It performs highly accurate leak detection of micro volume works. The sensor unit is a compact separate type, making it possible to install it close to the work.

Basic Specs.

Pressure range -100kPa to 700kPa
Power source voltage 100 to 240 VAC ±10%, 50/60 Hz, 70 VA max
Ambient temperature Operating temperature: 5 to 45℃
Storage temperature: -20 to 60℃
External dimensions W82 x D230 x H198
(Pneumatic Unit)
Weight Controller: Approx. 2.6 kg
Pneumatic Unit (LUA-231): Approx. 4.4 kg

Features / Functions

  • Intuitive operation with icons.
  • Monitoring of test pressure and differential pressure (leak) waveforms.
  • Compensates for noise effects on the works and reduces test time.
  • Multi-language (Japanese, English, Chinese).
  • USB port for easy data collection.
  • Sensor unit can be placed close to the work.
Measurement Performance Enhancing Features
  • High-performance differential pressure sensor

    The improved differential pressure sensor, which is the heart of the Air Leak Tester, and the high-performance AD converter have realized measurement stability in units of 0.1 Pa. These effects are expected to improve measurement accuracy and shorten test time.

  • Mastering/Master Preset

    Error components due to adiabatic compression, deformation, etc. during measurement are extracted and compensated using the value, enabling testing with a considerable error component, reducing measurement time and at the same time facilitating control on the master side. In addition, the system follows gradual environmental changes, such as room temperature, to achieve more stable measurements.

Safety and Reliability Enhancing Features
  • NR (Noise Reduction)

    When the leak limit is lowered to pursue accuracy or to shorten measurement time, the ratio of noise to the measured value will increase. In the Noise Reduction (NR) mode, indeterminate judgment areas are set for the initial Detection, and if the work falls within one of these areas, the noise component is removed by repeating Detection so that false rejection of good works can be reduced.

  • Exhaust Interference Prevention

    For a system with multiple leak testers, the exhaust process can cause large fluctuations in the source pressure. It can have a negative impact on the tester(s) that are still measuring. This function is provided to prevent this problem.

Functions related to the interface
  • USB memory data storage

    A USB memory can be used to store large amounts of data for long periods of time, and data can be easily transferred to a PC.

  • Multilingual

    Allows you to switch the display between multiple languages, including Japanese, English, and Chinese.

  • I/O monitor

    Check the connection of the signals with external PLCs, such as start/stop signals and pass/fail signals, on the screen. This is very useful when equipment is connected.

  • Quality management

    The latest 1000 work data (5000 for LS-R902) can be stored and displayed in a graph, which is useful for monitoring changes in work characteristics and changes in the measurement environment. In addition, the Mastering characteristic graph makes it easier to set test conditions.

Documents

  • * Please fill out the form to download.
  • LS-R740SS-985B1-ENGLISH CATALOG
  • LS-R740SS-985C1-D_240404
  • Manual (EN)
  • Manual (CN)
  • 2D DRAWING