PT-161A / PT-162A Pressure Transducers

  • Differential pressure/Gauge pressure
  • High responsiveness
  • Dual-use for gas and liquid
Highly responsive differential pressure sensor,
10 kHz frequency response
Highly responsive differential pressure transducer with 10 kHz frequency response.
PT-161A is for gas only, while PT-162A can measure differential pressure for both gases and liquids.
PT-162A has an air vent especially for measurement of water differential pressure.

Basic Specs.

Sensing element Fluoro silicone
Pressure media PT-161A: Air or noncorrosive gases
PT-162A: Water / air or noncorrosive liquids and gases
Pressure type Differential pressure, Gauge pressure (with Lo port open to the atmosphere)
Accuracy ±0.5 % of F.S.
(including the linearity, repeatability, and hysteresis)
Temperature characteristics Zero ±0.03 % of F.S./℃
Temperature characteristics Span ±0.03 % of F.S./℃
Allowable overpressure For 0 to 7 kPa and 0 to 35 kPa: 140 kPa
For 0 to 100 kPa: 300 kPa
Maximum line pressure Within the allowable overpressure
Response speed Frequency response 10 kHz
99% Step response 0.5 msec
Power source ±15 VDC(Current consumption: 10 mA or less)
External dimensions PT-161A:(W x H x D)42 x 44 x 39 mm
PT-162A:(φ x D)54 x 76(including 117 connector)mm
Weight PT-161A: Approx. 185 g
PT-162A: Approx. 500 g
Pressure inlet port Rc(PT)1/8
Operating temperature 5 to 40℃
Range 0 to 7 kPa
0 to 35 kPa
0 to 100 kPa
Output voltage 0 to 5 VDC
* Load resistance is 5 kΩ or more.
Signal connection PT-161A: Cable(2 m)included
PT-162A : Connector included without cable
Optional range High accuracy ±0.3% of F.S.
Documents Traceability related documents, Operation Manual
External dimensions PT-161A: W42 x D39 x H44
PT-162A: φ54 x 85 (135)

Features / Functions

Features

  • Test with high responsiveness (Frequency response 10 kHz)
  • PT-162A can be used for both gases and liquids.
  • PT-162A is splash proof type with an air vent and ideal for measurement of water differential pressure.
  • Differential pressure and gauge pressure can be measured with one unit.
  • Built-in amplifier minimizes the noise effect.

Option

As an option, PT-162A can be used as a digital pressure gauge in combination with a DP gauge indicator.