Flow Master FM-2C

FM-2C

Flow Master FM-2C is ideal for flow measurement and daily inspection of flow testers

FM-2C is a standard flowmeter with a fixed pressure and flow.
Unlike float-type flowmeters, there is no need to determine the flow using a regulator valve and no trouble such as damage to the float due to inrush pressure.

Edge & Function



Features

Customized to the specified pressure and flow.
Use as a standard for testing and comparing flowmeters.

● Improved long-term flow stability.

● Enhanced prevention of distortion during installation.

● Check the sensitivity of flow testers easily and reliably.

● Extremely low flow variation ensures long-time stable use.

● Use as a flow master for measuring deviation flow. (Test for ventilation and bore diameter of holes)

● 15% more compact than conventional products.

● The numerical value of the tester can be checked by connecting to the CAL port of the tester.

● Can be used in Flow Check (C-CHK), (F-CHK) of AF series.

● Joints for connecting to the piping available.

● Easy connection and disconnection with a plug.

● ISO/IEC17025 calibration available.

Example of use with our Air Flow Tester

Spec



FM-2C Production range

Customized to the desired flow. Use it as a reference instrument.
When placing an order, specify the test pressure and flow in the following ranges.

Test pressure Flow
Vacuum -89 to -50.1 kPa 200 mL/min to 5 L/min
-50 to -21.1 kPa 100 mL/min to 15 L/min
-21 to -10.1 kPa 100 mL/min to 10 L/min
-10 to -1 kPa 50 mL/min to 3 L/min
Pressure 1 to 10 kPa 50 mL/min to 3 L/min
10.1 to 21 kPa 100 mL/min to 10 L/min
21.1 to 51 kPa 200 mL/min to 15 L/min
51.1 to 100 kPa 0.3 L/min to 25 L/min
100.1 to 150 kPa 0.5 L/min to 35 L/min
150.1 to 200 kPa 0.5 L/min to 45 L/min
201 to 250 kPa 0.5 L/min to 55 L/min
251 to 300 kPa 0.5 L/min to 65 L/min
301 to 350 kPa 0.5 L/min to 70 L/min
351 to 400 kPa 0.5 L/min to 80 L/min

For specifications outside the production ranges, a request for quotation (RFQ) will be required.
201 to 209 mL/min is outside the standard production range.
2.01 to 2.09 L/min is outside the standard production range.

Minimum unit of test pressure (kPa)

Test pressure Range Minimum unit
Vacuum Down to -89 kPa 0.1
Pressure Less than 200 kPa 0.1
200 kPa or more 1

Accuracy (Difference from the required flow) & Minimum unit

Required flow Difference from the required flow Minimum unit
50 mL to 200 mL Accuracy (Difference from the required flow): Within ±10% 1 mL
0.21 L to 2.00 L 0.01 L
2.1 L to 80 L 0.1 L

For the flow above 200 mL/min, specify in units of L/min.

Main body: FM-2C
Accessories: (IN-side and OUT-side joints (1 set), O-ring (3 pcs.)

Classification



Model FM-2C(AB)(C,D)

Example:
HIGH-side joint:R1/2, LOW-side joint:Ø8 tube, Required flow:200 mL/min, Test pressure:10 kPa
FM-2C(R32)(200mL/min,10kPa)

A, B, C and D in the model notation are mandatory.

A HIGH-side joint R2 Port size R1/4
R3 Port size R1/2
R4 Port size Ø8 tube
B LOW-side joint Port size R1/4 *1
1 Port size R1/2
2 Port size Ø8 tube
C Required flow Please check the production range.
D Test pressure

*1 If the joint connection diameter of the LOW side is R1/4, leave the symbol of LOW joint blank.



Appearance